Axus PA-08 Instrukcja Obsługi Strona 204

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 252
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 203
Function MP
No. Bit
A B C Input AE-6
Entry value
reserved
X
Y
Z
IV
V
S
2600.0
2600.1
2600.2
2600.3
2600.4
2600.5
-
-
-
-
-
-
-
-
-
-
-
-
00
0
0
0
0
0
reserved
X
Y
Z
IV
V
S
2610.0
2610.1
2610.2
2610.3
2610.4
2610.5
-
-
-
-
-
-
-
-
-
-
-
-
00
0
0
0
0
0
reserved
X
Y
Z
IV
V
S
2620.0
2620.1
2620.2
2620.3
2620.4
2620.5
-
-
-
-
-
-
-
-
-
-
-
-
00
0
0
0
0
0
Holding current for height axes
X
Y
Z
IV
V
S
2630.0
2630.1
2630.2
2630.3
2630.4
2630.5
-
-
-
-
-
-
-
-
-
-
-
-
06
06
06
06
06
06
0 to
±
30 [A]
0
0
0
0
0
0
Movement monitoring
position and speed
X
Y
Z
IV
V
2800.0
2800.1
2800.2
2800.3
2800.4
-
-
-
-
-
-
-
-
-
-
02
02
02
02
02
0 to 99 999.999[mm]
0 = no monitoring
The position is calculated from the pulses of the
position encoder and from the pulses of the speed
encoder. If the difference of the results exceeds the
value of MP2800, the error message GROSS
POSITIONING ERROR <Axis> C is generated.
0
0
0
0
0
0
R H
1.0 TNC
415B/425/426
Machine Parameters MP 2600.0 - MP 2800.4 06.03.95 5.2 26
Przeglądanie stron 203
1 2 ... 199 200 201 202 203 204 205 206 207 208 209 ... 251 252

Komentarze do niniejszej Instrukcji

Brak uwag